6. APPLICATION FUNCTIONS
(5) Interrupt conditions (system parameters)
Set the values that designate ON for the bits that correspond to the factor of pass position interrupt
outputting to the parameter interrupt conditions (parameter No.0004) to validate the interrupt output of the
pass position interrupt.
Parameter No.0004 Interrupt conditions
Bit Abbreviation Name Bit Abbreviation Name
0 SYSE Current system error
8 OASF
Outputting with factor of other
axes start interrupt
1 CALM Current system alarm
9 PPI
Outputting with factor of pass
position interrupt
2
10
Reserved
3 11
4 Reserved 12
5 13
6 14
7
OCME Operation cycle alarm
15
API LIBRARY
Use the sscChange2Parameter/sscCheck2Parameter functions to set/get
interrupt conditions.